EUROBALISE BGA
Application
The cables are used as balise cables for ERTMS (European Rail Traffic Management System) railway networks. The cables are armoured and can provide low reduction factor.
Standard
- CEI 20-11
- CEI 20-14
- CEI 20-29
- CEI 20-34
- CEI 46-4
- CEI 103-10
Cable Construction
- Conductors: Solid annealed copper, 1.6 mm nominal diameter.
- Insulation: Solid polyethylene.
- Stranding: Conductors will be stranded with dielectric fi llers in order to get a circular core shape.
- Core Wrapping: Plastic tape (s) with overlapping.
- Inner Sheath: Low density polyethylene.
- Screen: Aluminium/polyethylene tape longitudinally applied and overlapped.
- Drain Wire: Tinned copper drain wire
- Intermediate Sheath: Low density polyethylene.
- Armour: Two galvanized steel tapes.
- Outer Sheath: Low density polyethylene.
Electrical Characteristics at 20℃
Nominal Conductor Diameter | mm | 1.6 |
Maximum Conductor Resistance (DC) | Ω/km | 21.5 |
Mutual Capacitance | nF/km | 42.3+/-15% |
Nominal Characteristic Impedance @8.9 KHz | Ω | 130 |
Nominal Characteristic Impedance @560 KHz | Ω | 110 |
Maximum Attenuation @560 KHz | dB/km | 3.8 |
Insulation Resistance | MΩ.km | 10000 |
Minimum Dielectric Strength core to screen (DC) | V | 1000 |
Minimum Dielectric Strength core to core (DC) | V | 3000 |
Reduction Factor @100V/km 50Hz | 0.6 |
Mechanical and Thermal Properties
- Minimum Bending Radius: 8×OD (static); 16×OD (dynamic)
- Temperature Range: -30℃ to +70℃ (during operation); -20℃ to +50℃ (during installation)
Dimensions and Weight
Cable Code | Number of Pairs | Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
||
---|---|---|---|---|---|---|
Inner | Inter. | Outer | ||||
1.6mm Conductor, 3.4mm Insulated Wire | ||||||
RS/BGA-2Y2Y(L)2YB2Y-1P1.6 | 1 | 1.0 | 0.8 | 1.6 | 16 | 334 |